Product Description
AGF-MxxT DC Multi-Circuits Monitoring Device for PV Combiner Box
Type | Description | Function | Optional function | |
AGF-M4T | 4 circuits DC0-20A Photovoltaic confluence detection | 1.3.5KV hall isolation 2.RS485 Modbus-RTU 3. Accuracy 0.5 class 4.0-1000V voltage measurement. 5.3 sets of external status inputs(optocoupler or dry contact mode) 6. The auxiliary power supply can be DC1000V and DC1500V. | 1.MJ (Analog input+ Relay output)-PT100/DC 4-20mA/DC0-10V+2 circuits normally open 2.B(power filter module) 3.L(LCD) 4.P2(Auxiliary power supply DC1000V) 5.P3(Auxiliary power supply DC1500V) | |
AGF-M8T | 8 circuits DC0-20A Photovoltaic confluence detection | |||
AGF-M12T | 12 circuits DC0-20A Photovoltaic confluencedetaction | |||
AGF-M16T | 16 circuits DC0-20A Photovoltaic confluence detection | |||
AGF-M20T | 20circuits DC0-20A Photovoltaic confluence detection | |||
AGF-M24T | 24 circuits DC0-20A Photovoltaic confluence detection |
| Multi-circuits Measurement up to 24 DC Circuits Input Channel: up to 24 Circuits LED Indicator for Re-flux, Disconnection, Over-current Rated Current: 20A Accuracy: 0.5 Class Voltage Measuring Range: up to 1500V (Busbar) |
| 3-Channel DI Switch Status Monitoring DI Status of Lightning Protector and DC CB Optocoupler or dry Contact |
| Temperature Measuring & Over-temperature Alarm Function Measuring the inner Temperature of the DC PV Junction Box Thermistor: NTC Range of Measuring: -20ºC~+100ºC |
| Keypads HMI for Programming Communication(address, baud rate and etc.) Over-temp Alarm Threshold |
| LCD Display English Interface Data Display |
| Easy Installation Perforated Hole for Cable to pass through DIN Rail Installation Module Connected by Data Line |
Item | AGF-M4T | AGF-M8T | AGF-M12T | AGF-M16T | AGF-M20T | AGF-M24T |
Input channels | 4 | 8 | 12 | 16 | 20 | 24 |
Rated current | DC 0~20A | |||||
Response time | 1s | |||||
Accuracy | 0.5 class | |||||
Temperature coefficient | 400ppm | |||||
RS485 communication | RS485/Modbus-RTU protocol,4800/9600/19200/38400bps | |||||
Additional function | ||||||
Switch input | 3-way input(optocoupler or dry contact mode) | |||||
General technical parameters | ||||||
Temperature/ Humidity | Working temperature: -35~+65ºC, humidity95%,no condensation, no corrosion gas place *Display module work temperature:-20~+70ºC | |||||
Temperature measurement function | To measure the inner temperature of the box (-20ºC~100ºC) | |||||
Altitude | ≤3000m | |||||
Insulation resistance | ≥100MΩ | |||||
Industrial frequency withstand voltage | power/communication/switching input/cell voltage input--AC 2kV/1min (When the auxiliary power supply is DC1500V, the withstand voltage between the power supply, photocell input and other circuits is AC 2.7kV) Current input/power, cell voltage, communication, switching state-AC3.5kV/1min | |||||
EMC | GB_T 17626.2-2006; Electrostatic discharge immunity test 3rd grade, air discharge 8kV, contact discharge 6kV. | |||||
| GB_T 17626.4-2008; Electrical fast transient immunity test grade 4, common mode 4kV, difference mode 2kV | |||||
| GB_T 17626.5-2008; Surge(shock) immunity test grade 4, common mode 4kV, difference mode 2kV | |||||
| GB_T 17626.8-2006; Power frequency magnetic field immunity test grade 4 |