Surge Protector for Lightning Protection Surge Protector Device Surge Protective Device RS485/RS232/Rtd/Tc Control Signal Lightning Arrester

Customization: Available
Task: Adjust
Structure: Combination

Products Details

Basic Info.

Model NO.
S-FLS
Condition
New
Customized
Customized
Material
PC
Nominal Voltage
24V/5V
Nominal Current
600mA
Total Nominal Discharge Current
15ka
Wiring
2-Wiring 3-Wiring
DC Maximum Continuous Working Voltage UC
6V
AC Maximum Continuous Working Voltage UC
4V
Transport Package
Box
Trademark
QIDIAN
Origin
Anhui China
HS Code
8536200000
Production Capacity
5000 Piece/ Week

Product Description

S-FLS Series Signal Surge Protectors
 
Lightning protection in the field of process measurement and control, providing signal protection for field devices such as transmitters, thermal resistances, solenoid valves, flow meters, valve positioners, frequency converters and other instruments. And the surge protection of I/O of control system such as AI, AO, DI, DO, PI of PLC.DCS. Widely used in petroleum, chemical, natural gas, environmental protection, new energy and other industries.

Surge Protector for Lightning Protection Surge Protector Device Surge Protective Device RS485/RS232/Rtd/Tc Control Signal Lightning ArresterSurge Protector for Lightning Protection Surge Protector Device Surge Protective Device RS485/RS232/Rtd/Tc Control Signal Lightning ArresterSurge Protector for Lightning Protection Surge Protector Device Surge Protective Device RS485/RS232/Rtd/Tc Control Signal Lightning Arrester
Surge Protector for Lightning Protection Surge Protector Device Surge Protective Device RS485/RS232/Rtd/Tc Control Signal Lightning Arrester
Surge Protector for Lightning Protection Surge Protector Device Surge Protective Device RS485/RS232/Rtd/Tc Control Signal Lightning Arrester
Surge Protector for Lightning Protection Surge Protector Device Surge Protective Device RS485/RS232/Rtd/Tc Control Signal Lightning Arrester


Basic Parameters:
Model S-FLS-2-5.EX S-FLS-2-24.EX
Nominal voltage Un 5V 24V
DC upper limit continuous working voltage Uc 6V 32V
AC upper limit continuous working voltage Uc 4V 22.5V
Universal nominal current lL 600ma 600ma
Total lightning impulse current limp(10/350 μs), D1 4KA 4KA
Lightning impulse current limp (10/350μs) per line, D1 2KA 2KA
Total nominal discharge current In(8/20 us), C2 10KA 10KA
Protection voltage Up (8/20 us), C2 L-L≤45V/L-PE≤600V L-L≤60V/L-PE≤600V
Protection voltage Up(1 kV/us), C3 L_L≤15V/L-PE≤600V L-L≤45V/L-PE≤600V
L-L≤45V/L-PE≤600V 100MHz 10MHz
Series impedance 180 180
Response timeTa <1ns <1ns
Intrinsically safe certified circuits Ex iallC T4/T5/T6 Ga Ex iaC II T4/T5/T6 Ga
Range of working temperature -40°C-+80°C -40°C-+80°C
Installation method 35mm DIN rail 35mm DIN rail
Grounding method Rail grounding/terminal grounding (optional) Rail grounding/terminal grounding (optional)
Connection Terminal Wire Specifications 0.2mm2 ~ 2.5mm2 0.2mm2 ~ 2.5mm2
Shell material PC PC
Flame retardant grade (UL94) V0 V0
Protection level IP20 IP20
Standard test IEC 61643-21/GB/T 18802.21 IEC 61643-21/GB/T 18802.21
Selection Guide:
Signal type SPD model Nominal voltage Un Nominal current IL Total nominal discharge current In (8/20us), C2 Wiring system
0(4)-20mA.
0-10V and other analog signals
S-FLS-2-24.EX 24V 600mA 10KA 2-wiring
S-FLS-3-24.EX 24V 600mA 15KA 3-wiring
Thermal resistance, thermocouple
wait for signal
S-FLS-2-5.EX 5V 600mA 10KA 2-wiring
S-FLS-3-5.EX 5V 600mA 15KA 3-wiring
Switch quantity (digital quantity)
wait for signal
S-FLS-2-24.EX 24V 600mA 10KA 2-wiring
S-FLS-3-24.EX 24V 600mA 15KA 3-wiring
RS-485, MODBUS
PRSFIBUS-DP,
CAN and other signals
S-FLS-2-5.EX 5V 600mA 10KA 2-wiring
RS-232 S-FLS-3-24.EX 24V 600mA 15KA 3-wiring
0(4)-20mA.
0~10V and other analog signals
S-FLS-2-24 24V 600mA 10KA 2-wiring
S-FLS-2-24 24V 600mA 15KA 3-wiring
S-FLS-2-24G 24V 600mA 10KA 2-wiring
S-FLS-3-24G 24V 600mA 15KA 3-wiring
Thermocouple, thermal resistance
wait for signal
S-FLS-2-5 5V 600mA 10KA 2-wiring
S-FLS-3-5 5V 600mA 15KA 3-wiring
S-FLS-2-5G 5V 600mA 10KA 2-wiring
S-FLS-3-5G 5V 600mA 15KA 3-wiring
Switch quantity (digital quantity)
wait for signal
S-FLS-2-24 24V 600mA 10KA 2-wiring
S-FLS-3-24 24V 600mA 15KA 3-wiring
S-FLS-2-24G 24V 600mA 10KA 2-wiring
S-FLS-3-24G 24V 600mA 15KA 3-wiring
RS 485, MODBUS.
RPOFIBUS-DP, CAM
wait for signal
S-FLS-2-5 5V 600mA 10KA 2-wiring
S-FLS-2-5G 5V 600mA 10KA 2-wiring
RS-232 S-FLS-3-24 24V 600mA 15KA 3-wiring
S-FLS-3-24G 24V 600mA 15KA 3-wiring
24V meter power supply S-FLS-2-24D 24V 10A 10KA 2-wiring
 

Promotions: 

1. All buyers enjoy guaranteed delivery within 3 days.

2. After the buyer uses it, give a good comment. 5% off your next purchase.

3. If the single consumption amount exceeds 1000 US dollars, enjoy priority delivery service.

4. Support customers' private customization services, parameters, appearance, packaging, etc. can be customized according to customer needs.

5. Customers represent our brand products, enjoy price protection and market protection policies, enjoy priority delivery, and private customized services.

After-sales service policy:

1. All buyers enjoy technical services, and professional technicians teach the use of products.

2. During the 2-year warranty period, if the product has quality problems, you can enjoy free maintenance services. If it cannot be repaired, you can replace it with a new one for free.

3. If it is not the quality problem of the product itself, it is due to the customer's use, causing the product to have quality problems, we provide free maintenance services, and the customer needs to bear the round-trip shipping. 

If you have any needs for the product, please contact TOM in time.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours